Line 17: Line 17:
 
! style="width: 10%" rowspan="2"|Designation
 
! style="width: 10%" rowspan="2"|Designation
 
! style="width: 20%" colspan="2"|[[Hydras|Hydra]] 16A Freestanding <br> Heated
 
! style="width: 20%" colspan="2"|[[Hydras|Hydra]] 16A Freestanding <br> Heated
! style="width: 10%"|[[Hydras|Hydra]] 17A Benchtop <br> Heated
 
 
|-
 
|-
 
! [[Hydras|Hydra]] 16A-S<br>''Standard''
 
! [[Hydras|Hydra]] 16A-S<br>''Standard''
 
! [[Hydras|Hydra]] 16A-T<br>''Tall''
 
! [[Hydras|Hydra]] 16A-T<br>''Tall''
! [[Hydras|Hydra]] 340
 
 
|-
 
|-
 
! Target <br> Users
 
! Target <br> Users
 
| colspan="2" | Industrial Manufacturing
 
| colspan="2" | Industrial Manufacturing
| Commercial Manufacturing
 
 
|-
 
|-
 
! Image
 
! Image
 
| colspan="2" | <gallery>File:Hydra_16A.png</gallery>  
 
| colspan="2" | <gallery>File:Hydra_16A.png</gallery>  
| <gallery>File:17A.png</gallery>
 
 
|-
 
|-
 
! Placement<br>Mechanism
 
! Placement<br>Mechanism
 
| colspan="2" | Freestanding (Floor) Model<br>Gantry Design  
 
| colspan="2" | Freestanding (Floor) Model<br>Gantry Design  
| Benchtop Model<br>Gantry Design
 
 
|-
 
|-
 
! Exterior Dimensions, <br> XxYxZ (closed)
 
! Exterior Dimensions, <br> XxYxZ (closed)
 
| 48x35x50 in <br> 120x88x125 cm
 
| 48x35x50 in <br> 120x88x125 cm
 
| 48x35x60 in <br> 120x88x153 cm
 
| 48x35x60 in <br> 120x88x153 cm
| 41x27x28 in <br> 104x69x71 cm
 
 
|-
 
|-
 
! Power <br> Requirements
 
! Power <br> Requirements
 
| colspan="2" | 15A / 110VAC / 60 Hz <br> 8A / 220VAC / 50Hz  
 
| colspan="2" | 15A / 110VAC / 60 Hz <br> 8A / 220VAC / 50Hz  
| 15A / 110VAC / 60 Hz <br> 8A / 220VAC / 50Hz
 
 
|-
 
|-
 
! Build Volume
 
! Build Volume
 
| 16x12x10 in <br> 400x300x250 mm <br> '''or'''<br> 24x16x10 in <br> 600x400x250 mm
 
| 16x12x10 in <br> 400x300x250 mm <br> '''or'''<br> 24x16x10 in <br> 600x400x250 mm
 
| 24x16x20 in <br> 600x400x500 mm
 
| 24x16x20 in <br> 600x400x500 mm
| 16x12x10 in <br> 400x300x250 mm
 
 
|-
 
|-
 
! Bed <br> Temperatures
 
! Bed <br> Temperatures
 
| colspan="2" | 120°C <br> ''200°C option'' <br> ''sub-ambient option''
 
| colspan="2" | 120°C <br> ''200°C option'' <br> ''sub-ambient option''
| 120°C <br> ''200°C option''<br> ''sub-ambient option''
 
 
|-
 
|-
 
! 200°C Hotbed <br> Note
 
! 200°C Hotbed <br> Note
| colspan="3" | ''Note that 200°C beds larger than 400x300mm require 230VAC for optimal heating.''
+
| colspan="2" | ''Note that 200°C beds larger than 400x300mm require 230VAC for optimal heating.''
 
|-
 
|-
 
! X/Y Printing<br> Speeds
 
! X/Y Printing<br> Speeds
 
| colspan="2" | Up to 50 mm/sec
 
| colspan="2" | Up to 50 mm/sec
| Up to 50 mm/sec
 
 
|-
 
|-
 
! Enclosure
 
! Enclosure
 
| colspan="2" | Heated to 55°C
 
| colspan="2" | Heated to 55°C
| Heated to 55°C
 
 
|-
 
|-
 
! Motion Control
 
! Motion Control
 
| colspan="2" | 3-Phase with <br> Closed-Loop Feedback
 
| colspan="2" | 3-Phase with <br> Closed-Loop Feedback
| 3-Phase with <br> Closed-Loop Feedback
 
 
|-
 
|-
 
! Positional Resolution <br> X/Y/Z in µm
 
! Positional Resolution <br> X/Y/Z in µm
 
| colspan="2" | 6 / 6 / 1
 
| colspan="2" | 6 / 6 / 1
| 6 / 6 / 1
 
 
|-
 
|-
 
! Positional Accuracy <br> X/Y/Z in µm
 
! Positional Accuracy <br> X/Y/Z in µm
 
| colspan="2" | 60 / 60 / 10
 
| colspan="2" | 60 / 60 / 10
| 60 / 60 / 10
 
 
|-
 
|-
 
! Positional Repeatability <br> X/Y/Z in µm
 
! Positional Repeatability <br> X/Y/Z in µm
 
| colspan="2" | 60 / 60 / 10
 
| colspan="2" | 60 / 60 / 10
| 60 / 60 / 10
 
 
|-
 
|-
 
! Precise X/Y Output <br> for Bioplots
 
! Precise X/Y Output <br> for Bioplots
 
| colspan="2" | 100 µm lines <br> 200 µm spacing
 
| colspan="2" | 100 µm lines <br> 200 µm spacing
| 100 µm lines <br> 200 µm spacing
 
 
|-
 
|-
 
! Precise Z output <br> for Bioplots
 
! Precise Z output <br> for Bioplots
 
| colspan="2" | 25 µm layers
 
| colspan="2" | 25 µm layers
| 25 µm layers
 
 
|-
 
|-
 
! Tool Positions <br> ''Optional''
 
! Tool Positions <br> ''Optional''
 
| colspan="2" | Five <br> ''Ten''
 
| colspan="2" | Five <br> ''Ten''
| Five
 
 
|-
 
|-
 
! Cold Flow <br> Options
 
! Cold Flow <br> Options
|colspan="3"| All [[EMO]], [[COD]], [[SDS]], [[CSD]], DSD and SMH Heads
+
|colspan="2"| All [[EMO]], [[COD]], [[SDS]], [[CSD]], DSD and SMH Heads
 
|-
 
|-
 
! Warm Flow <br> Options
 
! Warm Flow <br> Options
|colspan="3"| All [[VOL]], [[VCD]], [[KRA]] and [[KCD]] Heads
+
|colspan="2"| All [[VOL]], [[VCD]], [[KRA]] and [[KCD]] Heads
 
|-
 
|-
 
! Hot Flow <br> Options
 
! Hot Flow <br> Options
|colspan="3"| All [[MK1-250]], [[MK2-250]] and [[MK1-450]] Heads
+
|colspan="2"| All [[MK1-250]], [[MK2-250]] and [[MK1-450]] Heads
 
|-
 
|-
 
! Low Power <br> Laser Options
 
! Low Power <br> Laser Options
|colspan="3"| 5w, 808nm, AlGaAs Diode and/or 6w, 450nm, GaN Diode
+
|colspan="2"| 5w, 808nm, AlGaAs Diode and/or 6w, 450nm, GaN Diode
  
 
|-
 
|-
Line 108: Line 90:
 
| 40w ~10 µm, CO<sub>2</sub>
 
| 40w ~10 µm, CO<sub>2</sub>
 
| ''Not Applicable''
 
| ''Not Applicable''
| 40w ~10 µm, CO<sub>2</sub>
 
 
|-
 
|-
 
! Spindle Tool <br> Compatibility
 
! Spindle Tool <br> Compatibility
 
| colspan="2" | Standard <br> Three-Phase
 
| colspan="2" | Standard <br> Three-Phase
| Standard
 
 
|-
 
|-
 
! Other <br> Options
 
! Other <br> Options
|colspan="3"|Quiet Storm Fan, Microscope
+
|colspan="2"|Quiet Storm Fan, Microscope
 
|}
 
|}
  

Revision as of 15:01, 3 September 2018

Hydra Models

The Hydras are our Gantry models, introduced in 2016. In these models we move the heads in the X/Y and the bed only in the Z, allowing for faster print speeds and heavier fixturing.

Comparison

The following chart compares and contrasts the various Hydra models:

Printer Model Comparison
Designation Hydra 16A Freestanding
Heated
Hydra 16A-S
Standard
Hydra 16A-T
Tall
Target
Users
Industrial Manufacturing
Image
Placement
Mechanism
Freestanding (Floor) Model
Gantry Design
Exterior Dimensions,
XxYxZ (closed)
48x35x50 in
120x88x125 cm
48x35x60 in
120x88x153 cm
Power
Requirements
15A / 110VAC / 60 Hz
8A / 220VAC / 50Hz
Build Volume 16x12x10 in
400x300x250 mm
or
24x16x10 in
600x400x250 mm
24x16x20 in
600x400x500 mm
Bed
Temperatures
120°C
200°C option
sub-ambient option
200°C Hotbed
Note
Note that 200°C beds larger than 400x300mm require 230VAC for optimal heating.
X/Y Printing
Speeds
Up to 50 mm/sec
Enclosure Heated to 55°C
Motion Control 3-Phase with
Closed-Loop Feedback
Positional Resolution
X/Y/Z in µm
6 / 6 / 1
Positional Accuracy
X/Y/Z in µm
60 / 60 / 10
Positional Repeatability
X/Y/Z in µm
60 / 60 / 10
Precise X/Y Output
for Bioplots
100 µm lines
200 µm spacing
Precise Z output
for Bioplots
25 µm layers
Tool Positions
Optional
Five
Ten
Cold Flow
Options
All EMO, COD, SDS, CSD, DSD and SMH Heads
Warm Flow
Options
All VOL, VCD, KRA and KCD Heads
Hot Flow
Options
All MK1-250, MK2-250 and MK1-450 Heads
Low Power
Laser Options
5w, 808nm, AlGaAs Diode and/or 6w, 450nm, GaN Diode
High Power
Laser Options
40w ~10 µm, CO2 Not Applicable
Spindle Tool
Compatibility
Standard
Three-Phase
Other
Options
Quiet Storm Fan, Microscope

The Hydra Series

The Hydra 16A and 17A models have hard resolution (with encoder feedback) of 20 microns in the X and Y, and 0.8 microns in the Z in standard mode. In microstepping mode, we can achieve soft resolution of 4 microns in the X and Y. It comes standard with two tool positions, but can take additional yokes to handle more.

There are three models, as detailed above. The differences are:

  • The Hydra 16A-S (standard) has a 250mm Z and stands on the floor, with the following options:
    • Can take a bed at 400x300mm or 600x400mm at 120°C or 200°C, or a sub-ambient bed;
    • Can take the 40W CO2 laser and 5W, 450nm diode laser;
    • Can take the Pick and Place setup; and
    • Can take the 3-Phase and 1-Phase spindle tools.
  • The Hydra 16A-T (tall) has a 500mm Z and stands on the floor, with the following options:
    • Can take a bed at 400x300mm or 600x400mm at 120°C or 200°C, or a sub-ambient bed;
    • Can take the 5W, 450nm diode laser (NO CO2 LASER);
    • Can take the Pick and Place setup; and
    • Can take the 3-Phase and 1-Phase spindle tools.
  • The Hydra 17A has a 250mm Z and sits on a workbench or countertop, with the following options:
    • Can take a bed at 400x300mm at 120°C or 200°C, or a sub-ambient bed;
    • Can take the 40W CO2 laser and 5W, 450nm diode laser;
    • Can take the Pick and Place setup; and
    • Can take the 3-Phase and 1-Phase spindle tools.