Difference between revisions of "Emulsifiables"

From Hyrel3D
Jump to: navigation, search
(Settings)
(Settings)
Line 68: Line 68:
 
! style="width: 10%" | 51:1 Ratio
 
! style="width: 10%" | 51:1 Ratio
 
! style="width: 10%" | 100:1 Ratio
 
! style="width: 10%" | 100:1 Ratio
! style="width: 10%" | SDS-5
+
! style="width: 10%" | 5cc
! style="width: 10%" | SDS-10
+
! style="width: 10%" | 10cc
! style="width: 10%" | SDS-30
+
! style="width: 10%" | 30cc
! style="width: 10%" | SDS-60
+
! style="width: 10%" | 60cc
 
|-  
 
|-  
 
!colspan="9"| Material
 
!colspan="9"| Material

Revision as of 18:14, 2 September 2016

Overview

EMO-Type heads are for printing as follows:

  • With pastes, gels, emulsifiables or waxes.
  • At room or elevated temperatures.
  • With or without UV Crosslining.
  • With Hyrel Nozzles (1.5mm, 2mm) or Luer Tips.

These include the following:

EMO-Type Head Comparison
Temperature Ambient Up to 75°C Up to 100°C Up to 150°C
No Crosslinking EMO-25

SDS-5, -10, -30, -60

VSD-5, -10, -30, -60 VOL-25 KRA-15
With Crosslinking COD-25

CSD-5, -10, -30, -60

VCS-5, -10, -30, -60 VCD-25 KCD-15

So, what do these goofy designations actually stand for?

EMO: Emulsifiables at Room Temperature
COD: Emulsifiables T Room Temperature with Crosslink On Demand
VOL: Volcano: Heated (up to 100°C) Emulsifiables
VCD: Volcanic Crosslink on Demand
KRA: Krakatoa: Heated (up to 150°C) Emulsifiables
KCD: Krakatoic Crosslink on Demand
SDS: Syringe Dispensing System (uses disposable plastic syringes at room temperature)
CSD: Crosslinking Syringe Dispensing System
VSD: Volcanic Syringe Dispensing System
CVS: Crosslinking Volcanic Syringe Dispensing System

As of Sep 2016, the latest firmware is 32V, included with Repetrel 2.828.

Settings

Some settings for the EMO-Type heads (like temperature, prime/unprime values) will vary, depending on what material you are printing with. Nozzle diameter should accurately reflect what nozzle you have loaded (1.6mm is default) AND what path width you sliced for. Temperature commands will be ignored by heads with no temperature control. Having said that, here are our default shipping settings:

EMO-Type Head Comparison
Settings EMO, VOL, KRA, COD, VCD, KCD Heads
(17mm Tubes, Various Gear Ratios)
SDS, CSD, VSD, CVS Heads
(Various Tube Diameters, Standard Gear Ratios)
19:1 Ratio 27:1 Ratio 51:1 Ratio 100:1 Ratio 5cc 10cc 30cc 60cc
Material
Type Custom Custom Custom Custom Custom Custom Custom Custom
Color (any) (any) (any) (any) (any) (any) (any) (any)
Nozzle 1.600 1.600 1.600 1.600 1.600 1.600 1.600 1.600
Layer 0.300 0.300 0.300 0.300 0.300 0.300 0.300 0.300
Temp Info
Print Temp 35 35 35 35 0 0 0 0
Power Factor 100 100 100 100 100 100 100 100
Minimum 0 0 0 0 0 0 0 0
Maximum 0/100/200 0/100/200 0/100/200 0/100/200 0 0 0 0
Overrides
Pulses 1.600 2.300 4.700 8.500 0.750 0.580* 0.225 0.150
Feed Rate % 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000
Prime
Please note that Prime values will vary greatly from those shown, depending on the compressibility of your material.
Steps 600 700 1000 4000 200 200 300 500
Rate 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000
Dwell Time (ms) 100 100 110 120 100 100 100 100
Before Tool Change 1 1 1 1 1 1 1 1
Unprime
Please note that Unprime values will vary greatly from those shown, depending on the compressibility of your material.
Steps 500 550 800 3500 160 160 225 400
Rate 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000
Dwell Time (ms) 100 100 100 110 100 100 100 100
After Tool Change 1 1 1 1 1 1 1 1
Offsets
Clone Head Off Off Off Off Off Off Off Off
X 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000
Y 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000
Z 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000
Head Info
Model (varies) (varies) (varies) (varies) (varies) (varies) (varies) (varies)
RTD Type 1k PLAT_RTD 1k PLAT_RTD 1k PLAT_RTD 1k PLAT_RTD 1k PLAT_RTD 1k PLAT_RTD 1k PLAT_RTD 1k PLAT_RTD
Motor Current High High High High High High High High
Step Mode Sixteenth Sixteenth Sixteenth Sixteenth Sixteenth Sixteenth Sixteenth Sixteenth
* Thanks to Yasmine at VT for the precise calculation.