Difference between revisions of "Sekret!"

From Hyrel3D
Jump to: navigation, search
(Gcodes the customer shouldn't need)
(M797 Report Sensors)
Line 240: Line 240:
 
   >GB: B  0  0  0  0  0  0
 
   >GB: B  0  0  0  0  0  0
 
   >GB: C  0  0  0  0  0  0
 
   >GB: C  0  0  0  0  0  0
 +
 +
AX - Axis
 +
ST - Step
 +
DR - Direction
 +
HM - Home
 +
L1 - Limit 1
 +
L2 - Limit 2
 +
FT - Fault

Revision as of 19:05, 8 May 2020

Using the T with the ESR and 30M

T Commands and Variables for the ESR and 30M
Yoke
Image
YokePCA.png
Description 1st Slot No Slot 2nd Slot 3rd Slot 4th Slot
T Command T0 N/A T1 T2 T3
T Variable T11 N/A T12 T13 T14
Global Variable T10
Resistor Value 2,200 N/A 3,300 4,700 6,800

Using the T with the EHR and 16A (Single Yoke)

T Commands and Variables for the EHR and 16A (Single Yoke)
Yoke
Image
YokePCA.png
Description 1st Slot 2nd Slot 3rd Slot 4th Slot 5th Slot
T Command T0 T1 T2 T3 T4
T Variable T11 T12 T13 T14 T15
Global Variable T10
Resistor Value 2,200 3,300 4,700 6,800 10,000

Using the T with the 16A (Dual Yoke)

T Commands and Variables for the 16A (Dual Yoke)
Yoke
Image
YokePCA.png YokePCA.png
Description 2nd Yoke,
1st Slot
2nd Yoke,
2nd Slot
2nd Yoke,
3rd Slot
2nd Yoke,
4th Slot
2nd Yoke,
5th Slot
1st Yoke,
1st Slot
1st Yoke,
2nd Slot
1st Yoke,
3rd Slot
1st Yoke,
4th Slot
1st Yoke,
5th Slot
T Command T5 T6 T7 T8 T9 T0 T1 T2 T3 T4
T
Variable
T21 T22 T23 T24 T25 T11 T12 T13 T14 T15
Global Variable T20 T10
Resistor Value 1,500 2,700 3,900 5,600 8,200 2,200 3,300 4,700 6,800 10,000

Special Addresses

T Commands and T Variables for 16A Special Addresses
Description T Command T Variable Position Ω
All Devices n/a M# T0 n/a
All Heads n/a M# T100 n/a
Yoke 1, All Slots n/a M# T10 n/a
Yoke 2, All Slots n/a M# T20 n/a
Aux Port T10 n/a  ?
CO2 Laser T11 M# T41 22,000
3-Phase Spindle T12 M# T26 560
Primary Bed/Chamber n/a (T13) M# T91 0
Secondary Bed/Chamber n/a (T14) M# T92 12,000
All Beds/Chambers n/a M# T90 n/a


Gcodes the customer shouldn't need

M670 Toggle Y-Arm Light Now

Turn on Y-arm light immediately.

M671 Toggle X-Arm Lights

Toggle X-arm Lights

M672 Toggle Y-Arm with Sensor

See main Gcode page.

M673 Toggle Y-Arm Light Next

Toggle Y-arm light after all previous commands are finished.

M797 Report Sensors

Generates a text report of sensor states in 3D-View text window!

M797 I1 reports what is homed and what is not:

 >GB: AX ST DR  HM L1 L2 FT
 >GB: == == ==  == == == ==
 >GB: X  1  1   1  0  0  1
 >GB: Y  1  1   0  0  0  1
 >GB: Z  1  0   1  0  0  1
 >GB: A  0  0   1  0  0  1
 >GB: B  0  0   0  0  0  0
 >GB: C  0  0   0  0  0  0

AX - Axis ST - Step DR - Direction HM - Home L1 - Limit 1 L2 - Limit 2 FT - Fault